{"product_id":"vaillant-ecotec-plus-940-40kw-combi-boiler","title":"Vaillant ecoTEC Plus 940 40kW Combi Boiler","description":"\u003ch3 class=\"x1ll2q23 x1a4oops x132q4wb\"\u003eVaillant ecoTEC Plus 940 40kW Combi Boiler\u003c\/h3\u003e\n\u003cp class=\"x12ofw9d\"\u003eThe \u003cstrong\u003eVaillant ecoTEC Plus 940 Combi Boiler\u003c\/strong\u003e is a high-performance gas condensing boiler designed to provide dependable central heating and domestic hot water from a single appliance. With a powerful 40.8kW maximum domestic hot water output, a 94% ErP efficiency rating and a robust stainless-steel heat exchanger, it is a practical option for professional heating installations where strong hot water performance is a priority.\u003c\/p\u003e\n\u003cp class=\"x12ofw9d\"\u003eDesigned for gas engineers, boiler installers and heating contractors, the ecoTEC Plus 940 combines efficient operation with established Vaillant engineering. Its integrated storage-combi design makes it particularly important to assess the installation space, clearances and system requirements before specifying the unit.\u003c\/p\u003e\n\u003ch4 class=\"x1ll2q23 x1a4oops x132q4wb\"\u003eKey Features and Benefits\u003c\/h4\u003e\n\u003cul class=\"x12ofw9d\"\u003e\n\u003cli\u003e\n\u003cstrong\u003e40kW-class combi performance:\u003c\/strong\u003e Designed to deliver central heating and domestic hot water from one appliance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePowerful hot water delivery:\u003c\/strong\u003e Maximum domestic hot water heat output of 40.8kW, with a published flow rate of up to 21 litres per minute at a 30°C temperature rise.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e94% ErP efficiency:\u003c\/strong\u003e Supports efficient energy use when correctly installed, commissioned and operated.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStainless-steel heat exchanger:\u003c\/strong\u003e Built around a durable heat-transfer component designed for long-term heating system use.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModulating heating output:\u003c\/strong\u003e A published modulation ratio of up to 1:9 helps the boiler adjust its output to changing heating demand.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstaller-focused connections:\u003c\/strong\u003e Standardised gas, heating flow, heating return and domestic water connections support professional installation planning.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated filling loop:\u003c\/strong\u003e A filling loop is listed as supplied in the manufacturer's technical specification.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact-height format:\u003c\/strong\u003e Measures 720mm high, 440mm wide and 580mm deep, allowing installers to check suitability against available installation space.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow-noise operation:\u003c\/strong\u003e Published sound power level of 49dB(A).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVaillant engineering:\u003c\/strong\u003e A professional-grade heating appliance from an established boiler manufacturer.\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 class=\"x1ll2q23 x1a4oops x132q4wb\"\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cdiv class=\"x1n2onr6 xeuugli x193iq5w x3a0puf xv9y62a\"\u003e\n\u003cdiv class=\"x12ofw9d x193iq5w xeuugli xw2csxc xifltxc x7p5m3t\"\u003e\n\u003ctable class=\"x1vathgz x1gukg7c xezivpi xgqtt45 x1s8wshw x1fdb1hi\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\" class=\"xx0rg4r xj0a0fe xckciy2 xmi3gmm xvm2478 x5xtxb0 x1yc453h xso031l x1q0q8m5 xpps94y x1s688f x1ku3myg x3ajldb\"\u003eSpecification\u003c\/th\u003e\n\u003cth scope=\"col\" class=\"xx0rg4r xj0a0fe xckciy2 xmi3gmm xvm2478 x5xtxb0 x1yc453h xso031l x1q0q8m5 xpps94y x1s688f x1ku3myg x3ajldb\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"xx0rg4r xj0a0fe xckciy2 xmi3gmm xvm2478 x5xtxb0 x1yc453h xso031l x1q0q8m5 xsfyl8r x5o0mj3 x16dsc37\"\u003eBrand\u003c\/td\u003e\n\u003ctd class=\"xx0rg4r xj0a0fe xckciy2 xmi3gmm xvm2478 x5xtxb0 x1yc453h xso031l x1q0q8m5 xsfyl8r x5o0mj3 x16dsc37\"\u003eVaillant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"xx0rg4r xj0a0fe xckciy2 xmi3gmm xvm2478 x5xtxb0 x1yc453h xso031l x1q0q8m5 xsfyl8r x5o0mj3 x16dsc37\"\u003eProduct range\u003c\/td\u003e\n\u003ctd class=\"xx0rg4r xj0a0fe xckciy2 xmi3gmm xvm2478 x5xtxb0 x1yc453h xso031l x1q0q8m5 xsfyl8r x5o0mj3 x16dsc37\"\u003eecoTEC Plus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"xx0rg4r xj0a0fe xckciy2 xmi3gmm xvm2478 x5xtxb0 x1yc453h xso031l x1q0q8m5 xsfyl8r x5o0mj3 x16dsc37\"\u003eModel\u003c\/td\u003e\n\u003ctd class=\"xx0rg4r xj0a0fe xckciy2 xmi3gmm xvm2478 x5xtxb0 x1yc453h xso031l x1q0q8m5 xsfyl8r x5o0mj3 x16dsc37\"\u003e940\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"xx0rg4r xj0a0fe xckciy2 xmi3gmm xvm2478 x5xtxb0 x1yc453h xso031l x1q0q8m5 xsfyl8r x5o0mj3 x16dsc37\"\u003eBoiler type\u003c\/td\u003e\n\u003ctd class=\"xx0rg4r xj0a0fe xckciy2 xmi3gmm xvm2478 x5xtxb0 x1yc453h xso031l x1q0q8m5 xsfyl8r x5o0mj3 x16dsc37\"\u003eGas condensing combi boiler\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"xx0rg4r xj0a0fe xckciy2 xmi3gmm xvm2478 x5xtxb0 x1yc453h xso031l x1q0q8m5 xsfyl8r x5o0mj3 x16dsc37\"\u003eDomestic hot water output\u003c\/td\u003e\n\u003ctd class=\"xx0rg4r xj0a0fe xckciy2 xmi3gmm xvm2478 x5xtxb0 x1yc453h xso031l x1q0q8m5 xsfyl8r x5o0mj3 x16dsc37\"\u003e40.8kW maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"xx0rg4r xj0a0fe xckciy2 xmi3gmm xvm2478 x5xtxb0 x1yc453h xso031l x1q0q8m5 xsfyl8r x5o0mj3 x16dsc37\"\u003eCentral heating output\u003c\/td\u003e\n\u003ctd class=\"xx0rg4r xj0a0fe xckciy2 xmi3gmm xvm2478 x5xtxb0 x1yc453h xso031l x1q0q8m5 xsfyl8r x5o0mj3 x16dsc37\"\u003eUp to 32.3kW at 50\/30°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"xx0rg4r xj0a0fe xckciy2 xmi3gmm xvm2478 x5xtxb0 x1yc453h xso031l x1q0q8m5 xsfyl8r x5o0mj3 x16dsc37\"\u003eErP efficiency\u003c\/td\u003e\n\u003ctd class=\"xx0rg4r xj0a0fe xckciy2 xmi3gmm xvm2478 x5xtxb0 x1yc453h xso031l x1q0q8m5 xsfyl8r x5o0mj3 x16dsc37\"\u003e94%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"xx0rg4r xj0a0fe xckciy2 xmi3gmm xvm2478 x5xtxb0 x1yc453h xso031l x1q0q8m5 xsfyl8r x5o0mj3 x16dsc37\"\u003eHeating energy rating\u003c\/td\u003e\n\u003ctd class=\"xx0rg4r xj0a0fe xckciy2 xmi3gmm xvm2478 x5xtxb0 x1yc453h xso031l x1q0q8m5 xsfyl8r x5o0mj3 x16dsc37\"\u003eA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"xx0rg4r xj0a0fe xckciy2 xmi3gmm xvm2478 x5xtxb0 x1yc453h xso031l x1q0q8m5 xsfyl8r x5o0mj3 x16dsc37\"\u003eDomestic hot water energy rating\u003c\/td\u003e\n\u003ctd class=\"xx0rg4r xj0a0fe xckciy2 xmi3gmm xvm2478 x5xtxb0 x1yc453h xso031l x1q0q8m5 xsfyl8r x5o0mj3 x16dsc37\"\u003eA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"xx0rg4r xj0a0fe xckciy2 xmi3gmm xvm2478 x5xtxb0 x1yc453h xso031l x1q0q8m5 xsfyl8r x5o0mj3 x16dsc37\"\u003eHeat exchanger\u003c\/td\u003e\n\u003ctd class=\"xx0rg4r xj0a0fe xckciy2 xmi3gmm xvm2478 x5xtxb0 x1yc453h xso031l x1q0q8m5 xsfyl8r x5o0mj3 x16dsc37\"\u003eStainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"xx0rg4r xj0a0fe xckciy2 xmi3gmm xvm2478 x5xtxb0 x1yc453h xso031l x1q0q8m5 xsfyl8r x5o0mj3 x16dsc37\"\u003eModulation ratio\u003c\/td\u003e\n\u003ctd class=\"xx0rg4r xj0a0fe xckciy2 xmi3gmm xvm2478 x5xtxb0 x1yc453h xso031l x1q0q8m5 xsfyl8r x5o0mj3 x16dsc37\"\u003eUp to 1:9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"xx0rg4r xj0a0fe xckciy2 xmi3gmm xvm2478 x5xtxb0 x1yc453h xso031l x1q0q8m5 xsfyl8r x5o0mj3 x16dsc37\"\u003eHot water flow rate\u003c\/td\u003e\n\u003ctd class=\"xx0rg4r xj0a0fe xckciy2 xmi3gmm xvm2478 x5xtxb0 x1yc453h xso031l x1q0q8m5 xsfyl8r x5o0mj3 x16dsc37\"\u003e21L\/min at ΔT 30°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"xx0rg4r xj0a0fe xckciy2 xmi3gmm xvm2478 x5xtxb0 x1yc453h xso031l x1q0q8m5 xsfyl8r x5o0mj3 x16dsc37\"\u003eWeight\u003c\/td\u003e\n\u003ctd class=\"xx0rg4r xj0a0fe xckciy2 xmi3gmm xvm2478 x5xtxb0 x1yc453h xso031l x1q0q8m5 xsfyl8r x5o0mj3 x16dsc37\"\u003e60kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"xx0rg4r xj0a0fe xckciy2 xmi3gmm xvm2478 x5xtxb0 x1yc453h xso031l x1q0q8m5 xsfyl8r x5o0mj3 x16dsc37\"\u003eDimensions (H × W × D)\u003c\/td\u003e\n\u003ctd class=\"xx0rg4r xj0a0fe xckciy2 xmi3gmm xvm2478 x5xtxb0 x1yc453h xso031l x1q0q8m5 xsfyl8r x5o0mj3 x16dsc37\"\u003e720 × 440 × 580mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"xx0rg4r xj0a0fe xckciy2 xmi3gmm xvm2478 x5xtxb0 x1yc453h xso031l x1q0q8m5 xsfyl8r x5o0mj3 x16dsc37\"\u003eManufacturer article number\u003c\/td\u003e\n\u003ctd class=\"xx0rg4r xj0a0fe xckciy2 xmi3gmm xvm2478 x5xtxb0 x1yc453h xso031l x1q0q8m5 xsfyl8r x5o0mj3 x16dsc37\"\u003e0010036114\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"xx0rg4r xj0a0fe xckciy2 xmi3gmm xvm2478 x5xtxb0 x1yc453h xso031l x1q0q8m5 xsfyl8r x5o0mj3 x16dsc37\"\u003eLPG compatibility\u003c\/td\u003e\n\u003ctd class=\"xx0rg4r xj0a0fe xckciy2 xmi3gmm xvm2478 x5xtxb0 x1yc453h xso031l x1q0q8m5 xsfyl8r x5o0mj3 x16dsc37\"\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"xx0rg4r xj0a0fe xckciy2 xmi3gmm xvm2478 x5xtxb0 x1yc453h xso031l x1q0q8m5 xsfyl8r x5o0mj3 x16dsc37\"\u003eFilling loop\u003c\/td\u003e\n\u003ctd class=\"xx0rg4r xj0a0fe xckciy2 xmi3gmm xvm2478 x5xtxb0 x1yc453h xso031l x1q0q8m5 xsfyl8r x5o0mj3 x16dsc37\"\u003eSupplied, according to manufacturer specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"x1ll2q23 x1a4oops x132q4wb\"\u003eIdeal For\u003c\/h4\u003e\n\u003cp class=\"x12ofw9d\"\u003eThe Vaillant ecoTEC Plus 940 is intended for professional specification by Gas Safe registered engineers, plumbing and heating contractors, boiler installers and trade heating suppliers. Always confirm the property's hot water demand, heating requirements, gas supply, flue arrangements and installation clearances before ordering.\u003c\/p\u003e\n\u003ch4 class=\"x1ll2q23 x1a4oops x132q4wb\"\u003eOrder the Vaillant ecoTEC Plus 940\u003c\/h4\u003e\n\u003cp class=\"x12ofw9d\"\u003eChoose the Vaillant ecoTEC Plus 940 for a high-output combi boiler specification backed by Vaillant's engineering and technical documentation. Check compatibility with the proposed installation and confirm the contents of the supplied package before purchase.\u003c\/p\u003e\n\u003cp class=\"x12ofw9d\"\u003e\u003cstrong\u003eDelivery:\u003c\/strong\u003e Estimated delivery within 6–11 days, subject to stock availability and delivery confirmation.\u003c\/p\u003e\n\u003cp class=\"x12ofw9d\"\u003e\u003cstrong\u003eInstallation note:\u003c\/strong\u003e Installation, commissioning and gas work must be carried out by appropriately qualified and Gas Safe registered professionals in accordance with the manufacturer's instructions and applicable regulations.\u003c\/p\u003e","brand":"Vaillant","offers":[{"title":"Default Title","offer_id":60161028292992,"sku":"10036114","price":2652.01,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0745\/1449\/7816\/files\/Vaillant_ecoTEC_Plus_Combi_Boiler_1.avif?v=1792505755","url":"https:\/\/allgasltd.com\/products\/vaillant-ecotec-plus-940-40kw-combi-boiler","provider":"All Gas Wakefield Ltd","version":"1.0","type":"link"}